Introduction of product details


次氯酸330250.jpg

 

Hypochlorous Acid  Auto Making & Filling Machine

Features     Intelligent Control and Operation System

Ⅰ.Application:

Nowadays the world is under the global outbreak of covid-19 epidemic situation. At this just moment for the purpose to help people eliminate covid- 9 virus and completely  finish the pandemic, based on our mature patent disinfectant production technology, we newly developed and launched KN series Hypochlorous Acid Disinfectant Making & Filling Machine.

Salt + Water = HClO

With simple materials salt and water,we can easily make daily fresh,environmental and effective hypochlorous acid disinfectant of different concentration.It is applicable to deploy in supermarkets, hospitals,schools,hotels,communities,office buildings,shopping malls,airports,railway stations, enterprises and factories,etc.,which is convenient for people self-service paid or free filling to conduct public areas and home daily disinfection.

Ⅱ.Brief Introduction

The machine consists of three main parts, one RO unit (inside or outside type), one hypochlorous acid (HCIO) generator and one set self-service filling unit.The core equipment is the generator.It includes our patent  chip,one set of high-tech salt water electrolysis and hypochlorous acid processing equipment. It is scientific design, easy operation and maintenance,safe and reliable.

The hypochlorous acid disinfectant generated by the machine is safe and environmental,nontoxic and harmless, no pungent smell; it can effectively and quickly kill bacteria and viruses with a high sterilization rate up to 99.99%. 

Ⅲ.Main Specification

 1.   Model Features

 

Model

    HCIO Solution

Output(h)

           Auto Filling

   Power

Application

KN150X-X100

KN150X-X400

150,   100,   50ppm adjustable.

100L±10%

400L±10%

Any   volume   tanks quantitative freely.

  150VA

  310VA

Suitable  for  home  use, and some small groups.

 2.   Machine Specifications

 

 

 

Power Supply


220-260V/50Hz, ground resistance <100Ω

We adopt constant current power for electrolysis, which is controlled by the main control board to maintain the best current magnitude,the fluctuation range < ±0. 1A.   We installed a current sensor to detect the electrolytic current and provide overrun alarm and automatic protective shutdown.

Power  Consumptio 

DXY-H50-100, 0.12KW; matched RO unit, 0.25KW.

DXY-H150-400, 0.25KW, matched RO unit, 1.1KW.

Water  Supply

Mains water pressure  0.1-0.3MPa  (to  RO  unit);  (after  RO)  pure water feeding to generator 0.2-0.25MPa, temp. 10-35℃ , smooth drainage diameter ≥50mm.

Electrolytic Agent

Sodium chloride (NaCl), purity ≥99%, dissolves in water and generates saturated solution. (remainng more undissolved NaCl in solution to keep it in saturation state).

Electrolytic Agent

We adopt peristaltic pump to feed electrolytic cell with quantitative electrolytic agent stably and uniformly. Outside clear 50- 100L salt water tank with 1/2 salt & 1/2 water.

HCIO Output

Colorless  clear  hypochlorous  acid  solution  with  a  slight  chlorine  smell,  150ppm, 100ppm, 50ppm solution adjustable, pH 5.0-6.5, ORP (REDOX potential)≥800mV.

 



Hypochlorous acid in effective chlorine is 98%-99% (refer to our Test Report).


 

Output Ratio

Plan 1: HCIO and NaOH, 1:1; 1/2 HCIO solution remain, 1/2 NaOH will discharge.

Plan 2: add inert agent 5-7L per ton solution (50- 150ppm), 100% HCIO solution will generate and remain, no NaOH discharge. (Inert agent $4/L. Plan 1 or 2 is optional).

Control Ways

Microcomputer control, full automatic working and operation. Automatic alarm for the lack of pure water, salt water and current overrun, automatic protective shutdown.

Operation Interface

Push-button type panel, with a small screen for switch display of machine working condition data, such as electrolytic current, fault Code, cumulative working time, etc.

Auto Filling

Any  volume  tanks  quantitative  filling  freely  controlled   by   ultrasonic  liquid   level sensor.

Cabinet

Customized   machine  casing,  carbon   Steel  with   powder  coating,  steady  and beautiful.

Dimensions

KN150X-X100: 496x420x826cm3, 30kg; KN150X-X400: 496x420x826cm3, 33kg.

Warranty

Main machine: 1 year; Service time of electrolytic cell: 10000 hours guarantee.

 3.   RO Unit

It is essential that a Reverse Osmosis (RO) unit will be fitted to purify the mains water into pure water and feed to the generator and salt water tank as working media.

Ⅳ.Machine Features

1). Control panel

Push-button type panel

Easy recognition

 Easy operation

 Switch display working condition data

2). Reactor cell.

There is an operating hours' time accumulator recorder which can determine the life span of the electrolytic cell.

3). ORP, PH and PPM checking

There are machine attached ORP, PH and PPM checking instruments. It is suggested to check it every fortnight. PH and PPM values adjustments can be carried out through the control panel diagnostics with no need to enter the cabinet to act this.

4). Salt type

Fine powder domestic salt is preferred to large grain or tablets, although these do work.The finer the salt is, the quicker the dissolution into the water.

5). Continuous running

The unit operates most effectively when it is left to run continuously for a periods without frequent suspending. Constant stop/start routines should be avoided as this can imbalance the unit. Operators are best to fill the daily need in one session, rather than continually return to the appliance for top up  amounts. We suggest the minimum continuous working/production period/output is less than 50 liters.

6). Hose connections

The inlet and outlet hoses are colour coded, which makes the correct colour hose is attached to the matching connection point to avoid damaging the appliance.

7). Ventilation

Conventional room extract is sufficient to provide adequate ventilation for the appliance. Often open doors and windows to maintain the room ventilated. .

8). Water supply

The unit will be connected to the mains water supply, as well to be fitted with an on/off valve, and a 2 bar pressure reducing valve to allow the unit to be isolated for maintenance.A full set of Reverse Osmosis (RO) unit will be fitted to further reduce impurities and purify the means water.With the measures to make sure the water entering the generator must be of the purest possible quality or it will affect the performance, and shorten the service life.A low water alarm is fitted to provide warning of the lack of water to the unit. If this sounds, press MUTE button, or even turn the appliance off and check the reason.

9). Drain connection

A smooth bore drain out let of 50mm (China standard) is featured on the appliance but this can easily be reduced to suit UK standard pipe sizes of 38 or 42 mm.The drain discharge is liquid substance termed Catholyte,which is non-toxic and bio degradable,with no odour.

Important note:

 1.The above general data is for reference. Please consult the technical department of the company for specific parameters.

 2.The voltage Hertz of the device is selected according to the specific situation of each country.

Choose and trust us